Depending on the application, our components are set up as:
Transformer
Controlling choke through transformer utilization with an additional coil for:
- Control signals
- Monitoring of the saturation induction
- Current metering
- Setting of the quality factor and thermal relief of
the choke
- Specific setting of the inductance factor through
premagnetization of the magnetical material
Medium-frequency-transformers
Flux-compensating choke
For these applications SMP provides solutions in the range of:
Frequencies up to GHz-range
Currents up to 2000 A (special applications up to 3000 A
Saturation induction up to 2 Tesla
Setting of the inductance through variation of the permeability without any air-gap, through distributed air-gaps in the material
Sizes from 35 mm to 300 mm
Weights from 50 g up to 130 kg
Temperature class H (180° Celsius)
Specific setting of the:
Realizable through:
- seperate wound coil
- bifilar wound coil
- superimposed wound coil